Issue:
  TSS remained running.  *TSS9190A CA-TSS COMMAND PROCESSOR ABEND S0C4 IN TSSAUTH1+8D002 21.16.54 S0149446 CCSR010E TSSAUTHZ S0C4 at 1A2CE002 LMOD TSSAUTH CSECT TSSACOMP +00892A TSS16 N/A TSS16 21.16.54 S0149446 CCSR021I OWNER = CA TOP SECRET R16.0 21.16.54 S0149446 CCSR022I MODULE = TSSACOMP FMID = CAKOG00 RMID = RO89361 21.16.54 S0149446 CCSR061I PSW: 00000000 00000000 070C2000 9A2CE002 21.16.54 S0149446 CCSR062I ILC: 04 INTERRUPT CODE: 11 21.16.54 S0149446 CCSR067I COMPLETION CODE S0C4 REASON CODE 00000011 21.16.54 S0149446 CCSR063I TRANSLATION EXCEPTION ADDRESS: 00000000_1A593800 21.16.54 S0149446 CCSR064I DATA AT PSW 1A2CDFFC : A6305810 A6344490 B0CE4770 21.16.54 S0149446 CCSR065I HOME = 0030 PRIMARY = 0030 SECONDARY = 0030 21.16.54 S0149446 CCSR070I GR00 - GR01 00000000_00000028 00000000_1A592FF0 21.16.54 S0149446 CCSR070I GR02 - GR03 00000000_00000002 00000000_00000000 21.16.54 S0149446 CCSR070I GR04 - GR05 00000000_FFFFFFCE 00000000_0000000B 21.16.54 S0149446 CCSR070I GR06 - GR07 00000000_FFFFEF3A 00000000_1A2CE0BC 21.16.54 S0149446 CCSR070I GR08 - GR09 00000000_00D03000 00000000_0000000F 21.16.54 S0149446 CCSR070I GR10 - GR11 00000000_7F4B2048 00000000_1A2CDF48 21.16.54 S0149446 CCSR070I GR12 - GR13 00000000_1A2C56D8 00000000_7F4B20F0 21.16.54 S0149446 CCSR070I GR14 - GR15 00000000_1A1B5508 00000000_1A2CDF48 21.16.54 S0149446 CCSR071I AR00 - AR03 0000021C 00000000 00000000 00000000 21.16.54 S0149446 CCSR071I AR04 - AR07 00000000 00000000 00000000 00000000 21.16.54 S0149446 CCSR071I AR08 - AR11 00000000 00000000 00000000 00000000 21.16.54 S0149446 CCSR071I AR12 - AR15 00000000 00000000 00000000 00000000 21.16.57 S0149446 IEA794I SVC DUMP HAS CAPTURED: 463 463 DUMPID=002 REQUESTED BY JOB (TSS16 ) 463 DUMP TITLE=CCSR010E TSSAUTHZ S0C4 at 1A2CE002 LMOD TSSAUTH CSEC 463 T TSSACOMP +00892A TSS16 N/A TSS16 21.17.00 S0149446 IEA995I SYMPTOM DUMP OUTPUT 468 468 SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011 468 TIME=21.16.54 SEQ=00474 CPU=0000 ASID=0030 468 PSW AT TIME OF ERROR 070C2000 9A2CE002 ILC 4 INTC 11 468 ACTIVE LOAD MODULE ADDRESS=1A241000 OFFSET=0008D002 468 NAME=TSSAUTH 468 DATA AT PSW 1A2CDFFC - A6305810 A6344490 B0CE4770 468 AR/GR 0: 0000021C/00000028 1: 00000000/1A592FF0 468 2: 00000000/00000002 3: 00000000/00000000 468 4: 00000000/FFFFFFCE 5: 00000000/0000000B 468 6: 00000000/FFFFEF3A 7: 00000000/1A2CE0BC 468 8: 00000000/00D03000 9: 00000000/0000000F 468 A: 00000000/7F4B2048 B: 00000000/1A2CDF48 468 C: 00000000/1A2C56D8 D: 00000000/7F4B20F0 468 E: 00000000/1A1B5508 F: 00000000/1A2CDF48 468 END OF SYMPTOM DUMP 21.17.00 S0149446 *TSS9191I TSS COMMAND SUBTASK RECOVERY COMPLETE
Environment:
CA Top Secret for z/OS R16 on z/OS 2.2.
Resolution:
The TSS command abend occurred during a COMPARE request, the exact syntax of the command entered is this: TSS COMPARE(PRB5) USING(GJKP) The abend occurs due to incorrectly formed SITRAN entries on both of these users. The SITRAN object has been added to both users without any CICS transaction identified, it has been specified as blank. If you list the users you should see an entry that has no transaction value and looks like this: SITRAN = FACILITY = *ALL* The SITRAN object should be removed with the command 'TSS REM(xxxx) SITRAN'. If the user is supposed to be executing a transaction at logon to CICS then you can re-add the SITRAN object with the correct value. Once this is done you can run the COMPARE again and it should be successful. You may also want to check other users for a blank SITRAN value and correct as needed. Also note that the abend itself is not harmful other than the possibility of stranding command related storage in the Top Secret address space.