Dollar Universe AS400 node can't be started.

Document ID : KB000086131
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Affects Release version(s): 5

Error Message :
 In universe.log following error messages:
#################################
<< 2013-04-11 21:40:02 0008243/ /u_maj_fichier /000000000 - ERROR : cannot write in file /universe/RCCPRD/exp/data/u_fmhs50.dta
<< 2013-04-11 21:40:03 0008789/uxset /u_io_callsrv /000000000 - u_recv_msg error : Connection closed (host ¬|)*
#################################  

Patch level detected:Dollar Universe 5.1
Product Version: Dollar.Universe 5.1.1 FX24905

Description :Dollar Universe AS400 node can't be started.
Environment:
OS: IBM AS/400
OS Version: any version
Cause:
Cause type:
Configuration
Root Cause: Inspecting the IFS reveals that u_fmhs50.dta of EXP area is greater than 2 GB.
Resolution:
Reinitializing the history files to reduce their size.

- Load DU environment
- Stop DU
- Check all processes are well stopped
- Backup files mentionned below (locatd in the IFS of your company /exp/log)
CALL PGM(UXRAZFIC) PARM('u_fmsb50' 'X')
CALL PGM(UXRAZFIC) PARM('u_fmsp50' 'X')
CALL PGM(UXRAZFIC) PARM('u_fmtp50' 'X')

- Run a offline reorg
- Restart Dollar Universe

Fix Status: No Fix
 
Additional Information:
Workaround :
N/A