Some characters cause aborted execution.

Document ID : KB000086244
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
Error in the traced u_batch : 

###########
C:\WINDOWS\system32>set S_REPRISE=O 
The syntax of the command is incorrect. 

C:\WINDOWS\system32>set S_ID_APPLI=!> 
###########

Patch level detected:Dollar Universe 6.0.00
Product Version: Dollar.Universe 6.0.0

Description :Some characters used for the application id cause an aborted execution.
Environment:
OS: All
OS Version: All
Cause:
Cause type:
Defect
Root Cause: N/A
Resolution:
This is fixed since Dollar Universe v6.0.16.

Fix Status: Released

Fix Version(s):
Component: Application.Server
Version: Dollar.Universe 6.0.0
Additional Information:
Workaround :
N/A