A new IBM 3494 Tape Library has been added but the DYNAMCMS TDYNIBM synchronization does ignore all Volsers.

Document ID : KB000024836
Last Modified Date : 14/02/2018
Show Technical Document Details

Issue Symptoms:

A new IBM 3494 VTS Library has been added into the CA Dynam/T for z/VM configuration and all required changes have been implemented, but all VOLSERs located in the new IBMLIB libname  in Scratch Category C are ignored by the DYNAMCMS TDYNIBM synchronization between the Library and the Dynam catalog (CAICATL) ... 

 

Environment:

EXAMPLE: Of configuration changes made:

CADYNAMT SYSPROF: 
   IBMLIB ANDLIB02 1 07E0 07E1
   IBMLIB ATLH2 2 05C4 05C5     <=== new added Tape Library Name
DTPARMS ASSEMBLE: 
   CTLSCR=(CQ0000,CQ1999),
   IBM3495=YES,
All tapes are initialized with DYNCAT INT: 
   CADC800D ENTER DYNCAT COMMAND 
   INT 5C4 VOLSER=CQ1000 DEN=08E OWNER=2C
   CADC821I 5C4 CQ1000 INITIALIZED. 
   CADC800D ENTER DYNCAT COMMAND
   END 
   CADC823I DYNCAT END

Resolution:

After changes to the DTPARMS ASSEMBLE file have been made, Activator automatically regenerates the Dynam/T Modules. However, the System Adapter Modules must also be regenerated to incorporate the updated DTPARMS configuration.

To accomplish this, it is required to execute the following to bring it into status COMPLETE:

For CA Dynam/T for z/VM r3.0 execute this CA-CIS Task: Y430I003 Gen. System Adapter Modules   INCOMPLETE 09/02/03
For the CA Dynam/T for z/VSE Extension (DYNVM), execute: TQINST EXEC