A CA Database Analyzer statistics collection abends with S0C7 in module RALSTB.

Document ID : KB000044705
Last Modified Date : 14/02/2018
Show Technical Document Details

Problem:

Executing CA Database Analyzer for DB2 for z/OS (PDA) statistics collection and the job is abending with a S0C7 in module RALSTB. 

The following PDA message is returned: Collection of TS - dbname.tsname.nnnn - Abend0C7.

 

Cause:

The abend appears related to processing the object compression dictionary.

 

Resolution:

Complete a REORG of the object in question and verify that this resolves the S0C7 abend.