14.0 DBUTLTY Abend S0C4 DBRXIPR running REPORT AREA=RXX

Document ID : KB000116943
Last Modified Date : 04/10/2018
Show Technical Document Details
Issue:
Our customer is running a DR exercise and gets a S0C4  abend  in DBPRXIPR  when executing  DBUTLTY  REPORT AREA=RXX.   

 06:02:53  DB10089I - DBUTLTY ABEND HANDLER DRIVEN - NO ACTION REQUIRED         
 06:02:53  IEA995I SYMPTOM DUMP OUTPUT                                          
 06:02:53  SYSTEM COMPLETION CODE=0C4  REASON CODE=00000010                     
 06:02:53   TIME=06.02.53  SEQ=00393  CPU=0000  ASID=0103                       
 06:02:53   PSW AT TIME OF ERROR  078D1000   80017E20  ILC 6  INTC 10           
 06:02:53     ACTIVE LOAD MODULE           ADDRESS=00015000  OFFSET=00002E20    
 06:02:53     NAME=DBRXIPR                                                      
 06:02:53     DATA AT PSW  00017E1A - A0035AE0  E000D703  E000E000              
 06:02:53     AR/GR 0: 00000000/00020D5E   1: 00000000/00000000                 
 06:02:53           2: 00000000/000163C4   3: 00000000/00000000                 
 06:02:53           4: 00000000/1A203C6F   5: 00000000/00016884                 
 06:02:53           6: 00000000/009BEFC8   7: 00000000/1B08501C                 
 06:02:53           8: 00000000/1A213000   9: 00000000/0000E790                 
 06:02:53           A: 00000000/0000E9A0   B: 00000000/80015000                 
 06:02:53           C: 00000000/0000F000   D: 00000000/00016000                 
 06:02:53           E: 00000000/D501CA3A   F: 01000002/00000000                 
 06:02:53   END OF SYMPTOM DUMP                                                 
Environment:
z/OS 
CA Datacom 14.0
Cause:
RXX disk files were incorrectly transferred to the DR site.
Resolution:
RO82364 is already on.
No other PTFS found.
Datacom 14.0 is EOS so no new PTFs will be written by R&D.

First RXX input file was corrupted which lead to this abend.

Transfer the failing RXX disk file again to the DR site.