1-IDAETER102E - VSAM Error in CICS: See DATA-VIEW STATUS

Document ID : KB000093491
Last Modified Date : 30/04/2018
Show Technical Document Details
Issue:
During processing of CICS/IDEAL user transaction SR41, we get message
 
 1-IDAETER102E - VSAM Error in CICS: See DATA-VIEW STATUS 

The VSAM file is open in CICS. 
Environment:
z/VSE  
CICS Transaction Server 1.1.1 
CA IDEAL 11.0
IBM VSAM 
Cause:
In IDEAL installation job IDINS04 VSAM=NO has been coded so the IDEAL VSAM code has not been installed.
Resolution:
 Run  now 
// EXEC MSHP,SIZE=1024K
ARCHIVE 0202-ILV-B0-VS2         /* IDEAL VSAM */
INSTALL PRODUCT -
FROMTAPE ID='ILVVS2' -
PROD INTO=IDL110.IDL110
RETRACE
 /*

Further testing showed an ILLOGIC condition in IDEAL when reading VSAM files but that problem was not related to IDEAL but to FILES.